Heat Recovery On HAG Exhaust1 High Temperature Divertor Valves2 Hot Air Generators3 Waste Heat Recovery On Anneling Furnace4 Waste heat recovery on Burner Exhausts5 Waste Heat Recovery On RTO Exhausts6 Waste Heat Reocvery - Charge Preheater7 Biomass Briquette conversions8 WHR HWG On Melting Furnace Exhaust9 10 11 Waste Heat Recovery12
 
Other Products
 

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

Products
 

Waste Heat Recovery Systems on D.G. Set Exhausts ( Hot Water Generator )

 
By using waste heat in exhaust gases from D.G.Sets / Ovens. We Can generate steam, hot water, hot air.
 
D.G.Set Capacity - 750 KVA. (2Nos).
Waste Heat Recovery Systems on D.G. Set Exhausts ( Hot Water Generator )
Heat Recovery - 4,80,000 kcal/hr.
Water Inlet Temperature - 90 Deg.C.
Water Outlet Temperature - 105 Deg.C.
LPG Saving Per Hour - 43 kg/hr.
Cost Saving Per Year - Rs 19,35,000/year.(D.G. running 5/hr day x 300 days)
Pay Back Period - 7 months.
Request A Quote
 
 
 
 
 
 
 
 
 